- [RCBO] Residual Current Circuit Breaker with Overcurrent protection
- RCBO HSM1-2A type A 10kA 1P+N
- RCBO HSM1-4A type A 10kA 3P+N
- RCBO HSM2-2A type A 6kA 1P+N
- RCBO HSM2-4A type A 6kA 3P+N
- RCBO HSM2X-4A type A 6kA 3P+N
- RCBO HSM2-2B type B 6kA 1P+N
- RCBO HSM2-4B type B 6kA 3P+N
- [RCCB] Redisual Current Circuit Breaker
- RCCB HSL1-2A type A 10kA 1P+N
- RCCB HSL1-4A type A 10kA 3P+N
- RCCB HSL2-2A type A 6kA 1P+N
- RCCB HSL2-4A type A 6kA 3P+N
- RCCB HSL2-2B type B 6kA 1P+N
- RCCB HSL2-4B type B 6kA 3P+N
- RCCB HSL2-2EV type EV 6kA 1P+N
- RCCB HSL2-4EV type EV 6kA 3P+N
- TR Al/Cu Universal Terminal Block
- 16mm2 Al/Cu universal terminal block
- 35mm2 Al/Cu universal terminal block
- 50mm2 Al/Cu universal terminal block
- 95mm2 Al/Cu universal terminal block
- 150mm2 Al/Cu universal terminal block
- 240mm2 Al/Cu universal terminal block
- Terminal shroud for TR series Al/Cu universal terminal block
RCBO HSM2X-4A type A[G] 6kA
-
Share:
The HSM2 series 6kA type A 3P+N RCBOs (Residual current operated circuit breaker with integral overcurrent protection ) is the perfect solution for a complete protection against overcurrent and earth fault currents. In four and half modules width(81mm) the series ensure, at any time and under any condition, the safety of people, facilities and related equipment. Rated current reach to 50/63A.
Description
HSM2 series RCBO compliant to product standard IEC/EN 61009-1, IEC/EN 61009-2-1 and with the following main technical features:
• Breaking capacity
6,000 kA |
• Electromagnetic (IEC/EN 61009-1, IEC/EN 61009-2-1;
• Type A and Type AC;
• Sensitivity
10 | 30 | 100 | 300mA |
• Tripping characteristics curve
B | C |
• Rated current
50 | 63A |
Application benefits:
• Supply possible both from top and bottom;
• Fork type busbar connection (above and below) up to 16mm² and cable connection up to 25mm² cables;
• Easy troubleshooting and reduced downtime for maintenance operations thanks to the earth fault indicator (blue/red flag on the window);
Technical
Type | HSM2-2A | HSM2-4A | HSM2X-4A | |||
Standards | IEC/EN 61009-1, IEC/EN 61009-2-1; | |||||
Certificate | KEMA KEUR, CB, CE, UKCA, RoHS | |||||
Country of origin | CHINA | |||||
Electrical features |
Type (wave form of the earth leakage sensed) |
Type A, Type A[S], Type A[G] Type AC |
||||
Number of poles | 1P+N | 3P+N |
3P+N |
|||
Rated current | In | A | 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 A | 6, 10, 13, 16, 20, 25, 32, 40 A | 50, 63 A | |
Rated sensitivity | IΔn | mA | 10, 30, 100, 300 mA | 30, 100, 300 mA | 30, 100, 300 mA | |
Rated voltage | Ue | V | 220/230/240 V | 380/400/415 V | 380/400/415 V | |
Operating time | Type A / Type AC | Instantaneous | Instantaneous | Instantaneous | ||
Type A[S] | - | - | 10 ms delay | |||
Type A[G] | - | - | 40 ms delay | |||
Insulation voltage | Ui | V | 500V AC | |||
Overvoltage category | III | |||||
Pollution degree | 2 | |||||
Operating voltage of circuit test | V | 187 - 264 V | 230 - 485 V | 230 - 485 V | ||
Rated frequency | Hz | 50/60 Hz | ||||
Rated breaking capacity acc. to IEC/EN 61009-1 | Icn | A | 6,000 A | |||
Rated breaking capacity acc. to IEC/EN 60947-2 (Only referring to short circuit test) |
Icu | A | 10,000 A | |||
Ics | A | 5,000 A (50%Icu) | ||||
Rated residual breaking capacity acc.to IEC/EN 61009-1 |
IΔm | A | 3,000 A | |||
Rated impulse withstand voltage (1.2/50) | Uimp | kV | 4 kV | |||
Dielectric test voltage at ind. freq. for 1 min. | kV | 2.5 kV (50/60Hz, 1 min.) | ||||
Thermomagnetic release – characteristics | Characteristics B: 3In - 5In | |||||
Characteristics C: 5In - 10In | ||||||
Energy limiting class acc. to EN 61009-1 | 3 | |||||
Surge current resistance (wave 8/20) | A | 3,000 A | ||||
Mechanical features |
Housing | Insulation group I - II, RAL 7035 | ||||
Toggle | Insulation group II, RAL 5017 | |||||
Test button | Insulation group II, RAL 2000 | |||||
Contact position indication | Green / Red window | |||||
Electrical life | Operations | 4,000 cycles | ||||
Mechanical life | Operations | 10,000 cycles | ||||
Protection degree acc. to EN 60529 | Housing | IP4X | ||||
Terminals | IP2X | |||||
Shock resistance acc. to IEC/EN 60068-2-27 | 25g - 2 shocks - 13ms | |||||
Vibration resistance acc. to IEC/EN 60068-2-6 | 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz | |||||
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 | °C/RH | 28 cycles with 55°C/90-96% and 25°C/95-100% | ||||
Reference temperature for setting of thermal element | °C | 30 °C | ||||
Ambient temperature (with daily average ≤ +35 °C) | °C | -25… +40 °C | ||||
Storage temperature | °C | -40… +70 °C | ||||
* IEC/EN 60947-2 certificate and test-report are not available at present, the use of these values is the responsibility of the user | ||||||
Installation |
Terminal type | Twin-purpose terminal (lift / open-mouthed) | ||||
Terminal size for cables | bottom / top | mm² | 25/35 mm² | |||
Terminal size for PIN busbar | bottom / top | mm² | 10/16 mm² | |||
Terminal size for FORK busbar | bottom / top | mm² | M6 - 10/16 mm² | |||
Solid /stranded wiring |
1x 1mm² - 35mm² 2 x 1mm² - 16mm² * |
|||||
Flexible wires with or without ferrules |
1x 1mm² - 25mm² 2 x 1mm² - 10mm² * |
|||||
Tightening torque | bottom / top | 2 Nm | ||||
Stripping length of the cable | 10 mm | |||||
Mounting |
On DIN rail EN 60715 (35mm) by means of mounting clip |
|||||
Mounting position | Any | |||||
Connect from | Top/bottom terminals | |||||
Dimensions (H x W x D) | mm | 83 x 36 x 72 mm | 83 x 72 x 72 mm | 88 x 81 x 72 mm | ||
Weight | kg | 0.19 kg | 0.42 kg | 0.47 kg | ||
Package |
Packing A (Individual box) |
Quantity | pieces | 1 | 1 | 1 |
Dimension (H*W*D) | mm | 90*40*80 mm | 90*78*81 mm | 95*86*82 mm | ||
Weight | kg | 0.2 kg | 0.43 kg | 0.48 kg | ||
Packing B (*A) (Middle box) |
Quantity | pieces | 6 | 3 | 2 | |
Dimension (H*W*D) | mm | 255*95*91.2 mm | 242*98*89 mm | 200*90*87 mm | ||
Weight | kg | 1.3 kg | 1.3 kg | 1.3 kg | ||
Packing C (*B) (Master carton) |
Quantity | pieces | 60 | 30 | 20 | |
Dimension (H*W*D) | mm | 510*275*200 mm | 520*255*200 mm | 470*210*190 mm | ||
Weight | kg | 14.5 kg | 14.5 kg | 11 kg | ||
Combination with auxiliary elements |
Auxiliary contact | Yes | Yes | NA (yes) | ||
Allarm contact | Yes | Yes | NA (yes) | |||
Shunt trip | NA (yes) | NA (yes) | NA (yes) | |||
Auxiliary contact for bottom fitting | NA (yes) | NA (yes) | NA (yes) | |||
Undervoltage release | NA (yes) | NA (yes) | NA (yes) | |||
Overvoltage release | NA (yes) | NA (yes) | NA (yes) | |||
Motor operating device | NA (yes) | NA (yes) | NA (yes) |